Transthoracic echocardiography in the estimation of cardiac output in intensive care

Authors

  • Daniel Paz Martín MD PhD EDAIC EDIC. Sección de Cuidados Intensivos de la SEDAR. Complejo Hospitalario de Toledo

DOI:

https://doi.org/10.30445/rear.v10i2.640

Keywords:

Echocardiography, cardiac output, ICU, monitoring

Abstract

Cardiac output (CO) monitoring is a basic diagnostic and management tool in intensive care units (ICU). For this reason, guaranteeing the quality of SLN measurement procedures is a fundamental aspect of biomedical research and clinical practice.

For years, since its introduction in the 1970s, the pulmonary artery catheter (CAP) has been considered the gold standard for the intermittent measurement of CO by thermodilution.

In recent times we are witnessing a rapid implementation of echocardiography in ICUs. Transthoracic echocardiography (TTE) has been used to estimate SLN. The most commonly used form is based on the measurement of the area of the left ventricular outflow tract (LVOT) that is multiplied by the velocity-time integral at this point (IVT LVOT).

References

1) Vicho R. Parámetros Hemodinámicos Básicos en Ecocardiografí¬a. Rev electron AnestesiaR.
2) Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2015;16:233–70.
3) Quiñones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA, Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr. 2002;15:167–84.
4) Molina M. Otra piedra con la que no tropezar. AnestesiaR.org.
5) Carrasco J LL Jover LL El método de Bland-Altman para medir acuerdo. Med Clin (Barc) 2004;122(Supl 1):28-34.

Published

2020-09-10

How to Cite

Paz Martín, D. (2020). Transthoracic echocardiography in the estimation of cardiac output in intensive care. Revista Electrónica AnestesiaR, 10(2), 6. https://doi.org/10.30445/rear.v10i2.640

Issue

Section

Critical reviews of articles

Most read articles by the same author(s)

<< < 1 2 3 4 5 6