Emplazamiento occipital del sensor BIS®Quatro en neurocirugía con TIVA
BIS-vista occipital montage in patients undergoing neurosurgical procedures during propofol-remifentanil anesthesia. Dahaba AA, Xue JX, Zhao GG, Liu QH, Xu GX, Bornemann H, Rehak PH, Metzler H. Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Graz, Austria. Anesthesiology. 2010 Mar;112(3):645-51
DOI:
https://doi.org/10.30445/rear.v2i7.521Keywords:
Artículos GATIV, BIS, GATIV, Monitor, Monitorización GATIVAbstract
En ocasiones el abordaje quirúrgico frontal en neurocirugía impide usar el monitor de profundidad anestésica BIS. Con el propósito de valorar el comportamiento de dicho monitor con el sensor emplazado en la región occipital, y basados en la publicación de Shiraishi et al, los autores comparan los valores de BIS procedentes de dos localizaciones del sensor BIS® Quatro: frontal y occipital.
References
1. - Shiraishi T, Uchino H, Sagara T, Ishii N: A comparison of frontal and occipital bispectral index values obtained during neurosurgical procedures. Anesth Analg 2.004; 98:1773-5.
2. - Marsh B, White M, Morton N, Kenny GN: Pharmacokinetic model driven infusion of propofol in children. Br J Anaesth 1.991; 67:41- 8.
3. - Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1.986; 1:307-10.
4. - Niedhart DJ, Kaiser HA, Jacobsohn E, Hantler CB, Evers AS, Avidan MS: Intrapatient reproducibility of the BISxp monitor. Anesthesiology 2.006; 104:242- 8.
5. - Kent CD, Domino KB. Depth of anesthesia Curr Opin Anaesthesiol. 2.009 Dec;22(6):782-7.
6. - Johansen JW. Update on bispectral index monitoring. Best Pract Res Clin Anaesthesiol. 2.006 Mar;20(1):81-99.
7. - Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1.998 Oct;26(4):217-38.
8. - Schmidt ME, Steindorf K. Statistical methods for the validation of questionnaires-discrepancy between theory and practice. Methods Inf Med. 2.006;45(4):409-13.
2. - Marsh B, White M, Morton N, Kenny GN: Pharmacokinetic model driven infusion of propofol in children. Br J Anaesth 1.991; 67:41- 8.
3. - Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1.986; 1:307-10.
4. - Niedhart DJ, Kaiser HA, Jacobsohn E, Hantler CB, Evers AS, Avidan MS: Intrapatient reproducibility of the BISxp monitor. Anesthesiology 2.006; 104:242- 8.
5. - Kent CD, Domino KB. Depth of anesthesia Curr Opin Anaesthesiol. 2.009 Dec;22(6):782-7.
6. - Johansen JW. Update on bispectral index monitoring. Best Pract Res Clin Anaesthesiol. 2.006 Mar;20(1):81-99.
7. - Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1.998 Oct;26(4):217-38.
8. - Schmidt ME, Steindorf K. Statistical methods for the validation of questionnaires-discrepancy between theory and practice. Methods Inf Med. 2.006;45(4):409-13.
Published
2010-07-31
How to Cite
Ruiz Villén, M. C. (2010). Emplazamiento occipital del sensor BIS®Quatro en neurocirugía con TIVA: BIS-vista occipital montage in patients undergoing neurosurgical procedures during propofol-remifentanil anesthesia. Dahaba AA, Xue JX, Zhao GG, Liu QH, Xu GX, Bornemann H, Rehak PH, Metzler H. Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Graz, Austria. Anesthesiology. 2010 Mar;112(3):645-51. Revista Electrónica AnestesiaR, 2(7), 3. https://doi.org/10.30445/rear.v2i7.521
Issue
Section
Critical reviews of articles