Fick Principle in the determination of Cardiac Output.

Authors

  • Daniel Paz Martín Head of Section Anesthesiology and Resuscitation of the Toledo Hospital Complex, Toledo, Spain https://orcid.org/0000-0003-1702-5354
  • Rafael Dalmau Department of Anesthesiology, Hospital Español de Rosario, Rosario, Argentina
  • Ernesto Rioja-Corroto Resident Internal Physician of Anesthesiology and Resuscitation, Toledo University Hospital, Toledo, Spain.
  • Beatriz Castaño-Moreira Critical Cardiac Care Unit, Toledo University Hospital, Toledo, Spain

DOI:

https://doi.org/10.30445/rear.v14i12.1086

Keywords:

Fick Principle, Pulmonary artery catheter, Biophysics

Abstract

A key aspect in evaluating the hemodynamic status of the patient is the monitoring of cardiac output. Its determination offers an approximation to the global circulatory state, being one of the cardiovascular parameters standards  in the management of critically ill or high surgical risk patients.

Although the determination of cardiac output with a pulmonary artery catheter has fallen into disuse in the operating room and in the critical care management, it is important that the anesthesiologist-intensivist understands the biophysical bases of this monitoring.

Author Biography

Daniel Paz Martín, Head of Section Anesthesiology and Resuscitation of the Toledo Hospital Complex, Toledo, Spain

Doctor in Medicine
European Diploma in Anesthesia and Intensive Care
European Diploma in Intensive 
Head of Section Anesthesiology and Surgical Intensive Care. Complejo Hospitalario de Toledo.
President of AnestesiaR
Project Management Professional (PMP)

References

- Sette P, Dorizzi RM, Azzini AM. Vascular access: An historical perspective from Sir William Harvey to the 1956 Nobel prize to André F. Cournand, Werner Forssmann, and Dickinson W. Richards. J Vasc Access 2012; 13:137–44.

- Vincent JL, Fagnoul D. Do we need to monitor cardiac output during major surgery? Anesthesiology 2012; 117:1151-1152.

- Harvey S, Young D, Brampton W, Cooper AB, Doig G, Sibbald W et al Pulmonary artery catheters for adult patients in intensive care. Cochrane Database Syst Rev 2006:(3):CD003408.

- Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ et al A Randomized, Controlled Trial of the Use of Pulmonary-Artery Catheters in High-Risk Surgical Patients N Engl J Med 2003; 348:5-14

- Pappano AJ, Wier WG. The cardiac pump. En Cardiovascular physiology, 11ª ed. Philadelphia: Elsevier 2019:71-73.

- Krovetz LJ, Goldbloom S. Normal standards for cardiovascular data. I. Examination of the validity of cardiac index. Johns Hopkins Med J 1972;130:174–186.

- LaFarge CG, Miettinen OS. The estimation of oxygen consumption. Cardiovasc Res 1970;4:23–30.

- Bergstra A, van Dijk RB, Hillege HL, Lie KI, Mook GA. Assumed oxygen consumption based on calculation from dye dilution cardiac output: an improved formula. Eur Heart J 1995;16:698–703.

- Kendrick AH, West J, Papouchado M, Rozkovec A. Direct Fick cardiac output: are assumed values of oxygen consumption acceptable? Eur Heart J 1988;9:337–342.

- Wolf A, Pollman MJ, Trindade PT, Fowler MB, Alderman EL. Use of assumed versus measured oxygen consumption for the determination of cardiac output using the Fick principle.Cathet Cardiovasc Diagn 1998;43:372–380.

- Fegler G. Measurement of cardiac output in anesthetized animals by thermodilution method. QJExpPhysiol 1954;39:153

- Burchell SA, Yu M, Takiguchi SA, Ohta RM Myers SA. Evaluation of a continuous cardiac output and mixed venous oxygen saturation catheter in critically ill surgical patients. Crit Care Med 1997;25:388-391.

- Poli de Figueiredo LF, Malbouisson LM, Varicoda EY, Carmona MJ, Auler JO Jr, Rocha e Silva M. Thermal filament continuous thermodilution cardiac output delayed response limits its value during acute hemodynamic instability. J Trauma 1999;47:288-293. doi: 10.1097/00005373-199908000-00011.

- Mihaljevi T, vonSegesser LK, Tonz M Leskosek B, Seifert B, Jenni R, et al. Continuous versus bolus thermodilution cardiac output measurements: a comparative study. Crit Care Med 1995;23:944-949.

Published

2023-01-02

How to Cite

Paz Martín, D., Dalmau, R., Rioja-Corroto , E., & Castaño-Moreira , B. (2023). Fick Principle in the determination of Cardiac Output. Revista Electrónica AnestesiaR, 14(12). https://doi.org/10.30445/rear.v14i12.1086

Most read articles by the same author(s)

<< < 1 2 3 4 5 6 > >>