¿Cambia realmente la localización de la membrana cricotiroidea medida en posición neutra con la extensión de la cabeza y cuello? La ecografía nos abre los ojos.

Dixit A, Ramaswamy K K, Perera S, Sukumar V, Frerk C. Impact of change in head and neck position on ultrasound localisation of the cricothyroid membrane: an observational study. Anaesthesia 2019; 79(1): 29-32. Doi: 10.1111/anae.14445.

  • Natalia Muñoz Ávalos FEA Anestesiología, Reanimación y Terapéutica del Dolor. HU Puerta de Hierro, Madrid.
  • Jose Alberto Suarez Del Arco FEA Anestesiología, Reanimación y Terapéutica del Dolor. HU Puerta de Hierro, Madrid.
Palabras clave: difficult airway, cricothyroidotomy, ultrasound, cricothyroid membrane, Vía aérea difícil, cricotiroidotomía, membrana cricotiroidea, ecografía

Resumen

      El abordaje quirúrgico de urgencia de la vía aérea ante una situación “no intubable – no ventilable” es un escenario que implica, por parte del anestesiólogo, un adecuado entrenamiento que posibilite una resolución exitosa en el menor tiempo posible. Dada la poca frecuencia de esta práctica, muchos anestesiólogos optan por localizar la membrana cricotiroidea antes de realizar la inducción anestésica con la cabeza y cuello en posición neutra. Ante esto, y, considerando la posición ideal para una cricotiroidotomía al paciente con la cabeza y cuello en extensión, los autores de este artículo tratan de determinar si existe realmente cambio en la localización de dicha membrana con la variación de la cabeza y cuello de posición neutra a extendida así como si se modifica la altura de la misma. Para ello, realizan un estudio observacional con 22 voluntarios sanos a los que un radiólogo, con más de quince años de experiencia, mide con ecografía la distancia entre los bordes superior e inferior de la membrana y realiza una marca en el punto medio de la misma en las dos posiciones antes citadas. Los resultados obtenidos nos llevan a una importante reflexión que nos conduce a un cambio en el paradigma clásico de abordaje de la cricotiroidotomía.

ABSTRACT

Does the cricothyroid membrane location really change with the extension of the head and neck from neutral position? Ultrasound opens our eyes.

The emergency surgical approach of the airway to a situation "can’t intubate, can’t oxygenate’ is a scenario implies an adequate training on the part of the anesthesiologist that enables a successful resolution in the shortest posible time. In view of the low frequency of this practice, many anesthesiologists choose to locate the cricothyroid membrane before performing the anesthetic induction with the head and neck in a neutral position. Considering this and that the ideal position for a cricothyroidotomy is placing the head and neck in extension, the authors of this article try to determine if there is a change in the location of the membrane with the variation of the head and neck position from neutral to extended as well as if the height of the membrane is modified. To do this, hey performed an observational study with 22 healthy volunteers to whom a radiologist with more than fifteen years of experience measures with ultrasound the distance between the upper and lower membrane edges and makes a mark at the midpoint of the same in the two positions mentioned above. The results obtained from the study lead us to an important reflection that leads us to a change in the classical paradigm of approach of the cricothyroidotomy.

 

 

Citas

- Gadd KJ, Ganguly A, Mauldon EC. The inverted-V shape during transverse laryngeal ultrasonography for cricothyroid membrane localisation. Anaesthesia 2018; 73: 1572-1573.

- Gadd K, Kwok T, Sidhu S, Robertson I. Comparison of two transverse airway ultrasonography techniques for speed and accuracy to localise the cricothyroid membrane in obese female volunteers. British Journal of Anaesthesia 2019; 122 (2): e28-e31.

- Alerhand S. Ultrasound for identifying the cricothyroid membrane prior to the anticipated difficult airway. American Journal of Emergency Medicine 2018; 36 (11): 2078-2084.

- Oh H, Yoon S, Seo M, Oh E, Yoon H, Lee H, et al. Utility of the laryngeal handshake method for identifying the cricothyroid membrane. Acta Anaesthesiologica Scandinavica 2018; 62(9):1223-1228.

- Drew T, McCaul CL. Laryngeal handshake technique in locating the cricothyroid membrane: a non-randomised comparative study. British Journal of Anaesthesia 2018; 121 (5): 1173-1178.
Publicado
09-03-2020
Cómo citar
Muñoz Ávalos, N., & Suarez Del Arco, J. (2020). ¿Cambia realmente la localización de la membrana cricotiroidea medida en posición neutra con la extensión de la cabeza y cuello? La ecografía nos abre los ojos. Revista Electrónica AnestesiaR, 12(2), 2. https://doi.org/https://doi.org/10.30445/rear.v12i2.810
Sección
Lectura crítica de artículos